4 Determining IP Addresses
4-4
NJ-series CPU Unit Built-in EtherNet/IP Port User’s Manual (W506)
4-2 Built-in EtherNet/IP Port IP Address
Settings
Use one of the following methods to set the IP address of the built-in EtherNet/IP port.
Setting a User-specified IP Address
If you need to change the default IP address of the built-in EtherNet/IP port or if you need to use the
built-in EtherNet/IP port with another EtherNet/IP node, set the IP address to the required value.
Automatically Obtaining the IP Address from the BOOTP Server
There are two methods to automatically obtain an IP address.
Obtain the IP address from the BOOTP server each time the power is turned ON.
Obtain the IP address from the BOOTP server once when the power is turned ON and then do not
allow it to change.
4-2-1 Determining IP Addresses
BOOTP client
BOOTP command
BOOTP server
NJ-series Controller NJ-series Controller