6. Maintenance and Inspection
3.
Turn the 2 screws that x the plate cover anti-clockwise to remove them.
While pulling the plate cover toward you
, lift it up and remove the lower battery connector from the
eyehole.
Battery connector
Battery pack
(Upper)
Pullout label
(Pull this to remove.)
Remove the 2 screws.
4.
Hold the pullout label at the bottom of the battery pack and remove the battery pack.
Remove the upper and lower sections one by one.
Do not hold the connector or cable of the battery pack.
Use the red tape on the top of the battery pack, which is 10 cm from the inner edge of the battery, to
gauge how much further you need to pull the battery to remove it. Hold the battery securely with both
hands so as not to drop it.
1
2
Battery pack
(Lower)
Red tape

Table of Contents