EasyManua.ls Logo

Omron Powli BU75RW - Page 59

Omron Powli BU75RW
99 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
BU75RW/BU100RW/BU200RW/BU300RW
6
47
Procedure for recycling the battery
<BU75RW/BU100RW>
1.
Use a screwdriver to loosen (turn clockwise) the 2 screws at the top of the front panel of the unit,
until they turn freely. (The screws cannot be removed from the front panel.)
Pull the left side of the front panel towards you to remove it.
2.
Remove (turn clockwise) the screw that holds the plate cover in place.
Pull the right side of the plate cover towards you to remove it.
Loosen the 2 screws.
Pulltheleftsidetowardsyouto
removeit.②
Remove the screw.
①
Pull to the right
and towards you to
remove it.
②
3.
Disconnect the battery connectors
.
Hold here to disconnect.
A battery can present a risk of electrical shock and high short circuit current.The following pre-
cautions should be observed when working on batteries:
1) Remove watches, rings, or other metal objects from the hands.
2) Use tools with insulated handles.
3) Wear rubber gloves and boots.
4) Do not lay tools or metal parts on top of batteries.
5) Disconnect charging source prior to connecting or disconnecting batteries terminals.
Servicing of batteries should be performed or supervised by personnel knowledgeable of batter-
ies and the required precautions. Keep unauthorized personnel away from batteries.

Table of Contents

Related product manuals