7. Using the UPS monitoring software and contact signal
58
Using the UPS monitoring software
and contact signal
77
■
UPS monitoring software
“PowerAct Pro (for Windows/Linux)” , “UPS service driver” and “UPS Power Manager (Mac)” UPS
monitoring software is included with this product. Refer to the table below for details about compat-
ibility. Choose which one to use based on the application. Refer to the table below for details about
compatibility. For further details about the software functions, refer to the separate "UPS Monitoring
Software Quick Installation Guide."
* If you do not use the UPS monitoring software and contact signal, this
step is not required.
• UPS monitoring software selection table
Model OS Communication method UPS monitoring software
Required options
(sold separately)
Reference
BU75RW
BU100RW/
BU200RW/
BU300RW
Windows Vista Serial
(RS232C or USB 1.1)
PowerAct Pro (Note 1) -
→
See 7-1
Windows server2003
x64 Edition
Windows XP/2000
x64 Edition
Serial
(RS232C or USB 1.1)
PowerAct Pro (Note 1) -
→
See 7-1
UPS service (OS standard) + UPS service
driver (included software)
-
→
See 7-2
Contact signal (Note 2)
(Note 4)
UPS service (OS standard) BUC26
→
See 7-3
LAN Shutdown software for SNMP/web card SC20G
→
See 8-1
Windows server2003
Windows XP/2000
Serial
(RS232C or USB 1.1)
PowerAct Pro (Note 1) -
→
See 7-1
UPS service (OS standard) + UPS service
driver (included software)
-
→
See 7-2
Contact signal (Note 2)
(Note 3)
UPS service (OS standard) BUC26
→
See 7-3
LAN Shutdown software for SNMP/web card SC20G
→
See 8-1
Windows NT 4.0 Contact signal (Note 2)
(Note 3)
UPS service (OS standard) BUC26
→
See 7-3
LAN Shutdown software for SNMP/web card SC20G
→
See 8-1
Windows Me/98 Serial
(RS232C or USB 1.1)
PowerAct Pro (Note 1) -
→
See 7-1
Linux (Note:2) Serial
(RS232C or USB 1.1)
PowerAct Pro (Note 1) -
→
See 7-1
LAN Shutdown software for SNMP/web card SC20G
→
See 8-1
Mac OS X (10.3, 10.4)
Mac OS X Server (10.3,
10.4)
Serial
(USB 1.1)
UPS Power Manager (Note 5) -
→
See 7-1
LAN Shutdown software for SNMP/web card SC20G
→
See 8-1
Note 1: The most recent version can be downloaded from our homepage (http://www.omron.co.jp/ese/).
Note 2: Files cannot be automatically saved.
Note 3: To automatically stop the UPS, it may be necessary to change the PC’s BIOS settings.
Change the PC’s BIOS settings so that the PC’s power supply is not cut after OS shutdown is performed.
Note 4: The UPS automatically stops once the battery is depleted.
Note 5: Compatible only with Macintosh computers equipped with PowerPC CPU.
When this product is used in compliance with CE marking, please use under