37
9.4. Parameters Related to Internally Set Speed Control
No. 1 Internally Set
Speed
No. 1 Internally Set
Speed
Set the speed to use in the internally set speed
control.
● The default setting differs between SS2 and
G5 series.
No. 2 Internally Set
Speed
No. 2 Internally Set
Speed
No. 3 Internally Set
Speed
No. 3 Internally Set
Speed
No. 4 Internally Set
Speed
No. 4 Internally Set
Speed
No. 5 Internally Set
Speed
Soft Start
Acceleration Time
Soft Start
Acceleration Time
Set the acceleration/deceleration time to the
speed command inside the Servo Drive and the
internally set speed control.
● In both the SS2 and the G5 series, the default
setting is 0 ms.
● In both the SS2 and the G5 series, set the
acceleration/deceleration time of up to 1,000
r/min.
● Be careful in setting because the setting unit is
different.
* In both the SS2 and the G5 series, for
position control, set 0 ms to the soft start
acceleration/deceleration time.
Soft Start
Deceleration Time
Soft Start
Deceleration Time
Set the limit value of torque limits in units of %,
with the rated motor torque regarded as 100%.
● The default setting differs between SS2 and
G5 series.
● The torque limit function of the SS2 series is
enabled for both forward and reverse
operation.
● For the G5 series, you can use the setting of
Torque Limit Selection (Pn521) to set how to
limit torque.
• The default selection of Torque Limit
Selection (Pn521) is 1: No. 1 Torque Limit
(Pn013) for both forward and reverse
operation.