EasyManua.ls Logo

Omron R88M-K - Page 272

Omron R88M-K
730 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4 System Design
4-26
G5-series AC Servomotors and Servo Drives User’s Manual (with Built-in EtherCAT Communications)
z Main Circuit Connector Specifications (CNA)
z Motor Connector Specifications (CNB)
z Control Circuit Connector Specifications (CNC)
z External Regeneration Resistor Connector Specifications (CND)
Precautions for Correct UsePrecautions for Correct Use
Do not connect any External Regeneration Resistors between B1 and NC.
R88D-KN06F-ECT/-KN10F-ECT/-KN15F-ECT/-KN20F-ECT
Symbol Name Function
L1 Main circuit power supply
input
R88D-KNF-ECT
(600 W to 2 kW) : 3-phase: 380 to 480 VAC (323 to 528 VAC) 50/60 Hz
L2
L3
Symbol Name Function
U Motor connection
terminals
Red These are the output terminals to the Servomotor.
Be sure to wire them correctly.
VWhite
WBlue
Green/
Ye l l o w
Frame ground This is the ground terminal. Ground to 10 or less.
Symbol Name Function
24 V Control circuit power
supply input
24 VDC (21.6 to 26.4 VDC)
0 V
Symbol Name Function
B1 External Regeneration
Resistor connection
terminals
Normally B2 and B3 are shorted. Do not short B1 and B2. Doing so may
result in malfunctioning.
If there is high regenerative energy, remove the short-circuit bar between
B2 and B3 and connect an External Regeneration Resistor between B1
and B2.
B3
B2
NC Do not connect.

Table of Contents

Other manuals for Omron R88M-K

Related product manuals