9-5
9 Details on Servo Parameter Objects
G5-series AC Servomotors and Servo Drives User’s Manual (with Built-in EtherCAT Communications)
9-1 Basic Settings
9
*1 It is limited by the maximum torque of the connected motor.
Set the limit values for the motor output torques (3013 hex: External Torque Limit 1, 3522 hex:
External Torque Limit 2).
Refer to the Torque Limit Selection (3521 hex) for the torque limit selection.
During torque control, it limits the maximum torque in forward and reverse directions. The settings on
the Torque Limit Selection (3521 hex) and the External Torque Limit 2 (3522 hex) are ignored.
Set the value in units of 0.1% of the rated torque (100%).
E.g. When the set value is 1500, the maximum torque is limited to 150.0%.
Refer to 7-7 Torque Limit Switching on page 7-24 for the torque control and the torque limit selection.
Set the operating method for the 17-bit absolute encoder.
Explanation of Set Values
3013 hex
External Torque Limit 1
Setting range 0 to 5000 Unit 0.1 %
Default setting
5000
*1
Data attribute B
Size 2 bytes (INT16) Access RW PDO map Not possible.
3015 hex
Operation Switch when Using Absolute Encoder
Setting range 0 to 2 Unit
Default setting
2 Data attribute C
Size 2 bytes (INT16) Access RW PDO map Not possible.
Set value Description
0 Use as absolute encoder.
1 Use as incremental encoder.
2 Use as absolute encoder but ignore multi-rotation counter overflow.
All
Speed
200
100 (rating)
(rating)100
200
300
Torque [%]
300 (max)
(max)
Reversed
direction
Forward
direction
If 3013 and 3522 hex = 150.
All (semi)