EasyManua.ls Logo

Omron R88M-K - Page 649

Omron R88M-K
730 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
A-99
Appendices
G5-series AC Servomotors and Servo Drives User’s Manual (with Built-in EtherCAT Communications)
A-3 Sysmac Error Status Codes
App
A-3-1 Error Table
24680000 hex Motor Non-
conformity
The Servo Drive
and Servomotor
combination is not
correct.
The Servo Drive and
Servomotor combination is not
correct.
page A-130
24690000 hex Motor Non-
conformity
The Servo Drive
and Servomotor
combination is not
correct.
The Servo Drive and
Servomotor combination is not
correct.
page A-131
246A0000 hex Motor Non-
conformity
The Servo Drive
and Servomotor
combination is not
correct.
The Servo Drive and
Servomotor combination is not
correct.
page A-131
246B0000 hex Motor Non-
conformity
The Servo Drive
and Servomotor
combination is not
correct.
The Servo Drive and
Servomotor combination is not
correct.
page A-132
246C0000 hex Motor Non-
conformity
The Servo Drive
and Servomotor
combination is not
correct.
The Servo Drive and
Servomotor combination is not
correct.
page A-132
34E10000 hex Servo Drive
Overheat
The temperature of
the Servo Drive
radiator or power
elements exceeded
the specified value.
The ambient temperature of the
Servo Drive exceeded the
specified value.
Overload
page A-133
34E20000 hex Overload When the feedback
value for torque
command exceeds
the overload level
specified in the
Overload Detection
Level Setting (3512
hex), overload
protection is
performed
according to the
overload
characteristics.
Operation was continued for a
long time while overloaded.
There is incorrect wiring of the
motor line or a broken cable.
page A-134
34E30000 hex Regeneration
Overload
The regenerative
energy exceeds the
processing capacity
of the Regeneration
Resistor.
The load inertia is too large. Or,
the Servomotor rotation speed
is too high to absorb the
regenerative energy within the
specified deceleration time.
This Regeneration Resistor
cannot be used for continuous
regenerative braking. (The
operating limit of the external
resistor is limited to a 10%
duty.)
page A-135
34E40000 hex Error Counter
Overflow
Position error
pulses exceeded
the setting of the
Following error
window (6065 hex).
Motor operation does not follow
the command.
The value of the Following error
window (6065 hex) is small.
The encoder wiring is incorrect.
page A-136
Event code Event name Meaning Assumed cause
Level
Reference
Maj Prt Min Obs Info

Table of Contents

Other manuals for Omron R88M-K

Related product manuals