EasyManua.ls Logo

Omron R88M-K - Page 670

Omron R88M-K
730 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Appendices
A-120
G5-series AC Servomotors and Servo Drives User’s Manual (with Built-in EtherCAT Communications)
Event name External Encoder Status Error 0 Event code 080E0000 hex
Meaning Bit 00 of the external encoder error code (ALMC) was set to 1.
Source EtherCAT Master Function Module Source details Slave Detection
timing
Continuously
Error attributes Level Minor fault Recovery Error reset (after
cycling slave
power)
Log category System
Effects User program Continues. Operation Power drive circuit is OFF for relevant slave.
Indicators EtherCAT NET RUN EtherCAT NET ERR EtherCAT LINK/ACT
--- --- ---
System-defined
variables
Variable Data type Name
None --- ---
Cause and
correction
Assumed cause Remedy Prevention
Bit 00 of the external scale error code
(ALMC) was set to 1.
Check the external encoder
specifications and take suitable
corrective actions.
Take preventative actions according
to the external encoder specifications.
Attached
information
None
Precautions/
Remarks
“51” is displayed on the Servo Drive front panel and F051 is given as the AlarmCode (4001 hex).
Event name External Encoder Status Error 1 Event code 080F0000 hex
Meaning Bit 01 of the external encoder error code (ALMC) was set to 1.
Source EtherCAT Master Function Module Source details Slave Detection
timing
Continuously
Error attributes Level Minor fault Recovery Error reset (after
cycling slave
power)
Log category System
Effects User program Continues. Operation Power drive circuit is OFF for relevant slave.
Indicators EtherCAT NET RUN EtherCAT NET ERR EtherCAT LINK/ACT
--- --- ---
System-defined
variables
Variable Data type Name
None --- ---
Cause and
correction
Assumed cause Remedy Prevention
Bit 01 of the external encoder error
code (ALMC) was set to 1.
Check the external encoder
specifications and take suitable
corrective actions.
Take preventative actions according
to the external encoder specifications.
Attached
information
None
Precautions/
Remarks
“51” is displayed on the Servo Drive front panel and F151 is given as the AlarmCode (4001 hex).