7.2 List of Parameters
129
7.2 List of Parameters
<Conditions to Validate Settings>
A: Immediately validated after setting or changing
B: Validated when DEN = 1
(Do not change when DEN = 0. If any change is made when DEN = 0, safe operation cannot be
secured.)
C: Validated when the power supply is turned OFF and then ON again, or by sending CONFIG com-
mand.
Param-
eter
No.
Name Data
Size
Min.
Set Value
Max.
Set Value
Units Factory Set-
ting
Valida-
tion
Refer-
ence
Page
Pn000
Function
Selection
Basic Switch 0
2 0010 C 119
Pn00A
Filter Setting*
2 0000H 000FH 0000H A 118
Pn20E
Electronic
Gear Ratio
(Numerator)
4 1 1073741824 1 C 122
Pn210
Electronic
Gear Ratio
(Denominator)
4 1 1073741824 1 C 122
Pn304
JOG Speed
2 0 10000
min
-1
500 A
* The setting method is the same as for FIL rotary switch. Refer to 6.1 Filter Setting.
n.
4th
digit
3rd
digit
2nd
digit
1st
digit
Reserved
Reserved
Reserved
0
1
2 and 3
Sets CCW as forward direction.
Sets CW as forward direction.
(Reverse Rotation Mode).
Reserved (Do not change)
Rotation Direction Selection
1
Do not change.
0
Do not change.
0
Do not change.
TOEP_C710806_03A_1_0.book Seite 129 Montag, 2. Juli 2007 3:55 15

Table of Contents

Related product manuals