EasyManua.ls Logo

Omron SJDE-ANA-OY - Page 35

Omron SJDE-ANA-OY
170 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3.4 Main Circuit Wiring
33
5. Attach the connector to the SERVOPACK.
After wiring the connector, attach the connector to the SERVOPACK.
Note: 1. Pull lightly on the wires to confirm that they are securely connected.
2. Make sure that none of the insulating sheaths of the wires are caught in the
springs.
Connector for Power Supply/Regenerative Unit (CNA)
Pin No. Symbol Signal Name
1L1
Power supply input terminals
2L2
3+
Regenerative unit connection
terminals
4
YASKAWA
COM
ALM
RDY
FIL
L1
PWR
L2
U
V
W
CNBCNA
CN2
CN1
CN6
A/B
4
3
2
1
0
F
E
D
C
B
A
9
8
7
6
5
200V
SJDE
SERVOPACK
- 04ANA
A
4321
N
Power supply/Regenerative Unit connector
JZSP-CHG9-1
(Is supplied with the Servopack)
1
L2 L1
2
3
4
Power supply
Single-phase, 200 VAC
Molded-case circuit breaker
Noise filter
Magnetic contactor
AC reactor
Regenerative Unit
+(Y3)
Y4
Y5
C1
C2
CNA connector
FuseFuse
At the occurrence of alarms such as those for
regenerative resistor disconnection, regenerative
transistor (Tr) faults, and overvoltage, the contact
between terminals C1 and C2 will be open. Use
this contact signal to turn OFF the SERVOPACK
power supply.
TOEP_C710806_03A_1_0.book Seite 33 Montag, 2. Juli 2007 3:55 15

Table of Contents

Related product manuals