3.5 Connection Examples of Input Signal
44
3.5 Connection Examples of Input Signal
Connection Examples
Input current is 7 mA per point.
Prepare an external 24-VDC power supply. The 24-VDC power supply is not built into the
SERVOPACK.
• Specifications of the external power supply for sequence input signals:
24 VDC ± 1 V, 50 mA min.
The same power supply as that of the output circuit should be used.
∗ Twisted-pair wires
3.3kΩ
3.3kΩ
3.3kΩ
3.3kΩ
3.3kΩ
2
3
4
6
CN1
AVR2
24VDC
Power
Supply
+24V 0V
24VIN
/EXT1
/DEC
N-OT
P-OT
E-STP
Shield wire
Host Controller SERVOPACK
Photocoupler
Emergency
Stop
1
5
IMPORTANT