4.2 Main Commands
82
4.2.26 Constant Speed Feed (FEED: 36H)
Related Parameters
Byte FEED Description
Command Response
1 36H 36H
Processing clas-
sifications
Motion com-
mand group
Synchronization
classifications
Asynchronous
2 ALARM
Processing time Within commu-
nications cycle
Subcommand Can be used
3 OPTION STATUS • Performs constant speed feeding using the target speed (TSPD). The
servo performs constant speed feeding by position control. Use the Stop
Motion command (HOLD: 25H) to stop the constant speed feeding.
• Can be used during phases 2 and 3.
• A command warning will occur and the command will be ignored in the
following cases.
-If the SERVOPACK is Servo OFF: Command warning 1 (A.95A)
-If the target speed (TSPD) exceeds the maximum speed: Data setting
warning 2 (A.94B)
• OPTION field cannot be used. Set all bits to 0.
• The target speed (TSPD) is a signed 4 bytes. The direction is deter-
mined by the sign. The target speed is sent in the range from a negative
maximum speed to a positive maximum speed [reference unit/s].
• Changes can be made to the target speed during movement.
• Use DEN (output complete) to confirm the completion of position refer-
ence output.
• For details on posing commands, refer to 6.5.2 POSING Related Com-
mands for details on the operation.
4
5 MONITOR1
6
7
8
9 TSPD MONITOR2
10
11
12
13 SEL_MON
1/2
SEL_MON
1/2
14 IO_MON
15
16 WDT RWDT
17 For sub-
commands.
For sub-
commands.
18
19
20
21
22
23
24
25
26
27
28
29
Parameter No. Description
Pn80B Linear Acceleration Parameter
TOEP_C710806_03A_1_0.book Seite 82 Montag, 2. Juli 2007 3:55 15

Table of Contents

Related product manuals