4.3 Subcommands
93
4.3.7 Release Latch Mode (LTMOD_OFF: 29H)
4.3.8 Status Monitoring (SMON: 30H)
Byte LTMOD_OFF Description
Command Response
17 29H 29H
Processing
classifications
Control com-
mand group
Processing time Within commu-
nications cycle
18 - SUBSTATUS • Releases the modal latch mode.
This command has the same function as the main command
LTMOD_OFF.
19 SEL_MON
3/4
SEL_MON
3/4
20 - MONITOR3
21
22
23
24 MONITOR4
25
26
27
28 - -
29
Byte SMON Description
Command Response
17 30H 30H
Processing
classifications
Data communi-
cations com-
mand group
Processing time Within commu-
nications cycle
18 - SUBSTATUS • Reads the monitoring information specified in SEL_MON3/4.
This command has the same function as the main command SMON.
19 SEL_MON
3/4
SEL_MON
3/4
20 - MONITOR3
21
22
23
24 MONITOR4
25
26
27
28 - -
29
TOEP_C710806_03A_1_0.book Seite 93 Montag, 2. Juli 2007 3:55 15