AND8344/D
www.onsemi.com
17
Figure 36. LLC, maximum current on the primary
winding if output is shorted
Figure 37. LLC, maximum current on the primary
winding if secondary winding of the transformer is
shorted
Figure 38. LLC short overload, primary current,
output voltage and C53 voltage
Figure 39. LLC long overload, primary current,
output voltage and C53 voltage
Figure 40. LLC shorting of the output, primary
current, output voltage and C53 voltage. LLC
periodically tried to restart since short was held.
Once short disappears, output voltage is restored.
Figure 41. LLC shorting of the output, primary
current, output voltage and C33 voltage