19
Symptom Cause Remedy
No Water
Discharge
Pool water level too
low
Fill Pool to correct level.
Air leaks in inlet
ttings to pump.
Check and tighten all connections.
Teon tape ttings.
Short Filter Cycles
Filter Dirty Filter not backwashed for long
enough period.
Replace Media (Sand or Zelbrite)
Algae present in Pool
water.
DON’T RUN FILTER WITH LIVE
ALGAE IN POOL. Check the
chemical condition of pool water
and refer to Pool Water Chemical
Treatment. Note: Incorrect chemical
treatment will greatly shorten lter
cycle.
Filter Startup
Pressure High and
Water Flow Low
Filter requires
backwash
Follow backwash procedure outlined
in Manual.
Return Line restricted
Check for ow at return.
Filter Startup
Pressure Low and
Water Flow High
Skimmer Basket full
of leaves or debris
Clear Skimmer Basket of all foreign
matter and debris.
Pump Strainer Lid not
sealed corectly.
Refer to pump Owners Manual
for correct procedure for sealing
strainer lid correctly.
Pool water level too
low.
Fill Pool correct level.
Pump Impeller
Blocked
Call an authorised service agent to
service pump.
Blockage in suction
line
Air Leak in suction
line
Troubleshooting