ADJUSTMENT
PROCEDURES
Instruments
required
Dual
trace
oscilloscope,
Frequency
counter,
AF
oscillator,
Test
disc
(SONY
YEDS-18),
AC
voltmeter,
Jitter
meter,
and
Socket
P4(Part
no.
25050138)
{
1.
Focus
offset
adjustment
Load
the
test
disc
YEDS-18
on
the
tray
and
play
the
track
2.
Connect
the
oscilloscope
or
jitter
meter
to
terminal
P106.
(Oscilloscope)
Adjust
R109
until
a
clear
trace
of
waveform
pattern
as
shown
photo
1
appear
on
the
oscilloscope.
When
the
amount
of
jitter
is
broad,
set
R109
to
mechanical
center.
(Jitter
meter)
Adjust
R109
until
the
jitter
meter
reading
becomes
minimum.(Less
than
10ns.)
After
adjustment,
disconnect
the
oscilloscope
or
jittter
meter.
Oscilloscope
range
(
Vertical
:
0.SV/div.
Holizontal
:
0.5
ps/div.
DC,
Ground:
Center
le
af
00
eB
jarrnarr
N
-*.
Pn*.*.%.%.%,
Photo
1
2.
Tracking
offset
adjustment
Load
the
test
disc
YEDS-18
on
the
tray
and
play
the
track
2.
Turn
R116
to
minimum
position.(Counter
clockwise)
Connect
the
oscilloscope
between
pin
3
(TR)
of
P107
and
pin
2
(GND)
of
P106.
Adjust
R106
until
the
center
of
tracking
error
signal
on
the
oscilloscope
becomes
GND
level.
Turn
R116
to
the
mechanical
center.
After
adjustment,
disconnect
the
oscilloscope.
ort
hen.
P107
TR
Oscilloscope
P106
Vertical
:
500m
V/div.
Holizental
:
1
ms/div.
Photo
2
GND
DC,
Ground:
Center
—-20-