FR-N3X
6-4
TE
VC
EFBAL ADJUST
EFBAL=XXMO-W
EFBAL=XXMO-W
EFB =XXSAVE
EFBAL MO-W
EFBAL ADJUST
A
B
VC
ADJUSTMENT PROCEDURES-6
MD ADJUSTMENT
Adjustment of traverse (EF balance)
[Preparation]
(1) Connect oscilloscope to TE and VC on Extended JIG.
(2) Loading the MO disk to the unit.
[NOTE]
Do not connect the VC to the GND of the unit at test mode state.
To MD mechanism
Oscilloscope
Extended JIG
Part No. 0J12
[Adjustment]
(1) Turns MULTI JOG, and select to
EFBAL ADJUST
.
(2) Press MULTI JOG.
(3) Turn MULTI JOG, adjust so that reading of the waveform
currently observed with the oscilloscope should be as follows.
(4) Press MULTI JOG.
(5) Remove the oscilloscope and extended
JIG from MD mechanism.
(6) Take out disk from the unit by pressing EJECT.
Adjusted so that it may grow into A=B.
Extended JIG
Part No. 0J16