SERVICE PROCEDURE-1
Clear
Stand-by
CBL/SATON/STANDBY USB
No Strage
1. Replacing the fuses
3. To initialize the unit
1. Disconnect all cables except AC power code which are connected to unit.
2. Press USB button, and confirm "No Strage"on USB position.
3. Press ON/STANDBY button while pressing down CBL/SAT button when the unit is POWER ON, then the FL displays
"CLEAR", and turn to STAND-BY.
4. Do not touch until "clear "will be disappear from FL tube.(at least 5 seconds)
5. Remove power cord from wall outlet
Preset memory and each mode stored in the memory, are initialized and will return to the factory settings
This symbol located near the fuse indicates that the
fuse used is slow operating type, For continued protection against
fire hazard, replace with same type fuse, For fuse rating, refer to
the marking adjacent to the symbol.
Ce symbole indique que le fusible utilise est e lent.
Pour une protection permanente, n'utiliser que des fusibles de meme
type. Ce demier est indique la qu le present symbol est apposre.
F2000
F2000 or
F2002
F2002 or
F6901
F6901 or
F6902
F6902 or
F9100
F9100
F9100 or
2A-UL/T-233
2A-T/UL-ST2
4A-UL/T-233
4A-T/UL-ST2
15A-TUL-250V
15A-UL/T-314
15A-TUL-250V
15A-UL/T-314
10A-UL-ST6 N1
5A-SE-EAK
5A-SE-TL250V
252320GR
252253GR
252325GR
252257GR
252303GR
252197GR
252303GR
252197GR
252382GR
252078GR
252278GR
<MDC, MDF>
<MMA, MMP, MMQ, MMR>
<MMA, MMP, MMQ, MMR>
!
!
!
!
!
!
!
!
!
!
!
FUSE
FUSE
FUSE
FUSE
FUSE
FUSE
FUSE
FUSE
FUSE
FUSE
FUSE
REF NO. PART NAME DESCRIPTION PART NO. REMARKS
<Notes>
<MDC> : 120V,Canadian model
<MMP> : 230V,CE(European) country model
<MMA> : 230V,Australian model
<MMQ> : 220/230-240V,Hong kong model
<MMR> : 220/230-240V,Chinese model
<MDF> : 120V,Taiwanese model
2. Safety check out
(U.S.A. model only)
After correcting the original service problem, perform the following safety check before releasing the unit to the customer.
Leakage current Check
Measure the leakage current to a known earth ground (water pipe or conduct etc.) by connecting a leakage current
tester between the earth ground and exposed metal parts of the unit (input/output ground terminals, screw heads or metal overlays etc.).
Plug the power supply cord directly into a 120Vac 60Hz wall socket and turn ON/STANDBY button on.
Any current measured must not exceed 0.5mA.