functioning circuit, replace the batteries.
z If the unit still does not function as expected, send the
unit to repair.
2. Place the probe tip on or near the circuit or unit to be tested.
LED and audible beeper indicate the presence of AC Voltage
from 200~1000 VAC (50/60Hz).
Note: The voltage detector cannot detect voltage on armored cable
or on cable in conduit, behind panels, or in metallic enclosures.
Specifications
Indicators: LED and audible beeper
Voltage Range: 200~1000 VAC (50/60Hz)
Over voltage Category: Category III - 1000V
Pollution Degree: 2
Battery: Two 1.5 volt batteries (AAA, NEDA 24A or IEC LR 03)
Battery Replacement
1. Disconnect the unit from the circuit.
2. Remove the battery compartment cove.
3. Replace the batteries (observe polarity).
4. Replace the battery compartment cove.