M-10
Specifications Manual
13
9. Technical Specifications
Code reading is performed by positioning the aiming light over the center of a code. The conditions for
technical specifications are as follows, unless otherwise specified in each section.
<Conditions>
Temperature and humidity : Room temperature and room humidity
Ambient light : 100 ~200 lx (on the surface of a barcode)
Pitch angle : α= 0°
Skew angle : β = 15°
Tilt angle : γ = 0°
Curvature : R = ∞
Power supply voltage : 3.3 and 5.0 V
PCS (1D and 2D) : 0.9 or higher
Reading test : 1 read in 2 seconds or less. Accept the performance
with 90% or more success rate for 10 readings.
Barcode test sample (1D and 2D) : Specified below
<Barcode test sample>
1D codes OPTOELECTRONICS test samples
GS1 Databar, stacked codes, 2D codes Labels printed by a dedicated printer for barcode