M-10
Specifications Manual
14
9.1. Code Test Sample
1 D Barcodes
<Code 39>
Resolution Symbology PCS Size (mm) No. of Digits
0.127 mm (5mil) 32 × 10 15
0.20 mm (7.9mil) 100 × 10 31
0.254 mm (10mil)
Code 39 0.9
32.5 × 10 7
<Code 128>
Resolution Symbology PCS Size (mm) No. of Digits
0.20 mm (7.9mil) Code 128 0.9 42 × 10 16
<UPC/EAN>
Resolution Symbology PCS Size (mm) No. of Digits
0.330 mm (13mil) 100% UPC/EAN 0.9/0.3 31.5 × 25.0 12/13
GS1 Databar / Composite
<GS1-limited>
Resolution Symbology PCS Size (mm) No. of Digits
0.169 mm (6.7mil) Limited 0.9 12 × 1.5 14
0.169 mm (6.7mil) Limited-Composite 0.9 12 × 3.0 26
2 D Codes
<PDF417>
Resolution Error Correction PCS Size (mm)
No. of Character
0.169 mm (6.7mil) 23 × 10
0.254 mm (10mil)
Level-3 0.9
35 × 15
58
<QR Code: Model-2>
Resolution Error Correction PCS Size (mm)
No. of Character
0.169 mm (6.7mil) 5 × 5
0.212 mm (8.4mil) 6 × 6
0.381 mm (15mil)
M 0.9
11 × 11
44
<Data Matrix>
Resolution Model PCS Size (mm)
No. of Character
0.212 mm (8.4mil) 5 × 5
0.254 mm (10mil)
ECC200 0.9
6 × 6
40
Note: The size is outline dimensions excluding quiet zone.