9.6. Pitch, Skew, and Tilt
Pitch : α = ± 50°
Skew : β = ± 50°
Tilt : γ = 360°
<Conditions>
Barcode : 0.33 mm UPC/EAN specified in Section 9.1
Distance : 65 mm from the front edge of the Scanner
Curvature : R =
For the pitch angle and tilt angle measurement, set the skew angle β = +1
Figure 12: Pitch, Skew, and Tilt
9.7. Curvature
0.33 mm UPC/EAN : R 20 mm
<Conditions>
Barcode : 0.33 mm UPC /EAN specified in Section 9.1
Distance : 45 mm from the front edge of the scanner
Angle
: α = 0°, β =15°, γ = 0°
Figure 13: Curvature
* The reading characteristics may deteriorate due to the specular reflection of LED illumination when the
reflectivity is high.