SPECIFICATIONS MANUAL
Optical Specifications
7
7.1 Basic Specifications
Item
Characteristics
Scan method
CCD linear image sensor
-
Effective pixel
Horizontal
1500 dots
Image capture speed (*1)
Scan rate
300 scans/sec
View angle
Horizontal
Approx. 50°
Light source
Red LED
-
Peak wavelength
624 nm
Maximum radiation output (*2)
12 lm
*1 The fastest seed of image capture.
*2 Reference value based on the datasheet.
(Ambient air temperature 25°C, luminous efficacy 60lm/W, If = 100 m)
7.2 Aiming Pattern
The aiming is used for the following purpose:
1. Light source for bar code reading
2. Light source to indicate the appropriate reading range
The aiming specifications are as follows:
An optical axis of imaging field of view and the center of horizontal aiming width coincide at a
distance of L=86±10 mm from the front edge of the scanner.
The horizontal aiming width to the horizontal width of imaging field of view at a distance of
L=86 mm is 100%±10%.
Figure 7: Aiming Pattern and Imaging Range