Manual No. 25-ULGPMU01-01 Series OPT Handheld
CCD Scanner
Page 17
Setting the Number of
Characters to be Scanned
ZZ
Start/End
Program
Menu
-[[-
H0
Fixed length
OFF
all codes
-I1-
Β
H1
Fixed length
ON
all codes
-I2-
HK
Fixed length
ON
selected codes
-IL-
HL
Min. length
selected codes
-IM-
HM
Max. length
selected codes
-IN-
Setting Code Specific Options - Options for specific codes may be configured affecting:
* Enabling and disabling code variants and translations.
* Data verification such as by mean of a check digit calculation. A check digit has a value that can be
calculated from the other data characters and is usually the last data character in a bar code.
* Pre-editing of the data string such as removing the check digit and/or ST/SP characters.
The more common options are described here.
Check CD - Enables the check digit calculation. If the calculated check digit does not correspond to the check digit
in the bar code, then the bar code is ignored. The use of a check digit greatly improves the security of a bar code.
Do Not Check CD - Disables the check digit calculation. This option is required when the bar codes do not contain
a check digit or contain an invalid check digit.
Transmit CD - Enables the transmission of the check digit together with the data characters. If the check digit
calculation is disabled, the reader cannot differentiate anymore between a (valid) check digit and a data character. It
will therefore transmit all data characters of the label, including what could constitute a check digit.
Do Not Transmit CD - Disables the transmission of the check digit. If the check digit calculation is disabled, the
reader cannot differentiate between a (valid) check digit and a data character. It will therefore transmit all data
characters of the able, excluding the character that could constitute the check digit for the type of bar code.
Transmit ST/SP - Enables the transmission of the start and stop characters of a bar code.
Do Not Transmit ST/SP - Disables the transmission of the start and stop characters of a bar code.