English
- 36 -
ORUS RF Programmable Thermostat User Manual
Measured and displayed temperature resolution: 0.1°C
Temperature regulation range: 2.0°C ÷ +35°C
Measurement update: every 20 seconds
Measurement precision: ± 0.5°C
Winter or summer or manual operation
Optional display in °F
Automatic change CET / DST
Password protected keypad lock for installation in public places
Wall mounting (or on 503 type box)
Radio Frequency remote actuator control
Operating temperature: 0 °C ÷ +50 °C
Operating humidity: 20% ÷ 90% noncondensing
Storage temperature -10°C ÷ +65°C
Degree of protection: XXD
Maximum distance between thermostat and actuator: 100 m in free field
The preset temperature values (expressed in °C) are the following:
funct. winter funct. summer
T1 5.0 OFF
T2 15.0 23.0
T3 18.0 25.0
T
MANUAL 20.0 24.0
Regulation of temperature levels is subjected to the following condition: T1 ≤ T2 ≤T3.
In summer mode, T1 cannot be set and corresponds to the air conditioning OFF.
REMOTE ACTUATOR
For details about technical specifications refer to the remote actuator documentation
supplied with the instrument.