Connection
−13−
5 Connection
This chapter explains how to connect the speed controller, power supply, motor and others.
When operating a motor, be sure to connect the control DC power supply in addition to the AC power supply.
5.1 Connecting method
Control DC power supply
24 VDC±10%
150 mA or more
L (Live)
N (Neutral)
Capacitor
Speed controllerMotor
AC power
supply
Fuse
Single-phase 100 V 50/60 Hz
Single-phase 110/115 V 60 Hz
Single-phase 200 V 50/60 Hz
Single-phase 220/230 V 50/60 Hz
Grounding
Grounding
Note
For the AC power supply voltage of the speed controller, be sure to use the same power supply
voltage as the motor specication.
Ensure that the connector plugged in securely. Insecure connection may cause malfunction or
damage to the motor or speed controller.
How to wiring the CN1 and CN4 connectors
Insert the lead wire while pushing the button of the orange color with a
screwdriver.
Manufacturer PHOENIX CONTACT GmbH & Co. KG
Model
CN1: FKCT 2,5/6-ST-5,08
CN4: DFMC 1,5/8-ST-3,5
Connect the I/O signals
to CN4 on the speed
controller
Refer to p.15