Connection
−14−
5.2 Connecting the AC power supply and capacitor
Connect the AC power supply and capacitor to the CN1 on the speed controller.
Applicable cable size: AWG18 to 14 (0.75 to 2.0 mm
2
)
*
*
AWG20 to 14 (0.5 to 2.0 mm
2
) for capacitor connection
Lead wire strip length: 10 mm (0.39 in.)
If crimp terminals are used, select the following terminals.
Manufacturer: PHOENIX CONTACT GmbH & Co. KG
Model: AI 0,5-10 [Conductor cross-sectional area: 0.40 to 0.65 mm
2
(AWG20)]
*
AI 0,75-10 [Conductor cross-sectional area: 0.65 to 0.82 mm
2
(AWG18)]
AI 1-10 [Conductor cross-sectional area: 0.82 to 1.2 mm
2
(AWG18)]
AI 1,5-10 [Conductor cross-sectional area: 1.25 to 1.8 mm
2
(AWG16)]
AI 2,5-10 [Conductor cross-sectional area: 2.0 to 3.0 mm
2
(AWG14)]
*
For capacitor connection
CN1 pin assignments
Pin No. Connection Description
1
Capacitor Connects the capacitor.
2
3 N.C. Not connected.
4
AC power supply
Connects a live wire.
5 Connects a neutral wire.
6 FG Connects a grounding wire.
Connecting the capacitor
There are four terminals in the supplied capacitor, and the
terminals A-B and C-D are internally connected as shown in the
gure.
Connect either of the terminals A or B and either of the terminals
C or D to the speed controller.
Use the supplied capacitor cap to insulate the capacitor terminal
connection.
Capacitor
FASTON terminals
187 series
Capacitor cap
A
B
C
D
*
Manufacturer: TE Connectivity
Connecting the earth leakage breaker
Install an earth leakage breaker to the AC power line to protect the primary circuit.
Recommended device Mitsubishi Electric Corporation: NV series
Connecting the fuse
Be sure to connect a fuse or similar device in the AC power line to protect against overcurrent.
Fuse rating
Single-phase 100/110/115 V 216 Series (Littelfuse,Inc.) 10 A or equivalent
Single-phase 200/220/230 V 216 Series (Littelfuse,Inc.) 6.3 A or equivalent
5.3 Connecting the motor and speed controller
Connect the motor cable connector to the CN3 on the speed controller.
Use a connection cable (supplied or accessory) when extending the wiring distance between the motor and speed
controller. The connection cable can be connected up to 3 pieces. The wiring distance between the motor and speed
controller can be extended to a maximum of 10.5 m (34.4 ft.).
Flexible connection cables are also available as accessories.
Note
Ensure that the connector plugged in securely. Insecure connection may cause malfunction or
damage to the motor or speed controller.