EasyManua.ls Logo

Oriental motor DSC Series - Multi-Speed Operation

Oriental motor DSC Series
44 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operation
−23−
6.8 Operating in two or more speeds (multi-speed operation)
The multi-speed operation can be performed by setting the rotation speed and switching the ON/OFF status of the
M0 and M1 inputs.
Data setting method
(Example: Rotation speed)
Power ON
Display on the
operation panel
Rotation speed:
0 r/min (Initial value)
Data
mode
Press two times
Setting screen
Data No.0:
Operation data
No.0
Setting the rotation speed
The display blinks
The desired operation
data number can be
selected from the
operation data No.0 to
No.3 (4 data) by
pressing .
You can select the desired
data by pressing .
Rotation speed (rEv0)
Acceleration time (tA0)
Deceleration time (td0)
Initialization (ini0)
Select other operation data number to set data.
Keep pressing the key until
the display becomes "1000"
Rotation speed:
0 r/min (Initial value)
Setting
The display blinks
Determines the data
Blinks a few times fast
Press
Press two times
Press
Press
Press
Press
Data No.0
selection
screen
Data No.
selection
screen
Refer to "7.2 Operation panel transitions" on p.26 and p.27 for panel transitions.
Operating method
Operate the motor by selecting any of the operation data No.0 to No.3 based on a combination of ON/OFF status of the M0 and
M1 inputs.
The motor is operated using the rotation speed, acceleration time, and deceleration time in the selected operation data number.
«Operation procedure»
1. Select the operation data number using the M0 and M1 inputs.
2. When either of the FWD input or REV input is turned ON, the motor will rotate.
3. Switch the operation data number using the M0 and M1 inputs.
4. When the FWD input or REV input which has been turned ON is turned OFF,
the motor will stop.
ON
OFF
ON
OFF
ON
OFF
FWD
input
No.0
No.1
No.2
No.3
M1
input
M0
input
Motor movement
Operation
data No.
M1 M0 Description
0 OFF OFF
Operation panel setting/
remote setting
*
1 OFF ON
Operation panel setting2 ON OFF
3 ON ON
*
When the "external speed command input" parameter is set
to "ON (Enable)" (initial value: OFF), the rotation speed
can be set using an external potentiometer or external DC
voltage.