7.5 Setting the parameters
Parameter list
Operation mode: Parameter mode
Item Display Description Setting range
Initial
value
Speed reduction ratio
Gr-r
When setting the speed reduction ratio with
respect to the rotation speed of the motor output
shaft, the speed being converted by the speed
reduction ratio can be displayed. If the conveyor
speed reduction ratio is calculated and input, the
conveyor transfer speed can also be displayed.
1.00 to 9999 1.00
Speed increasing ratio
Sp-r
When increasing the motor rotation speed
using the external mechanism and others, the
converted speed can be displayed.
1.00 to 5.00 1.00
Lowest digit display xing
DG0F
In the speed stability of this product, the display
of the last digit on the rotation speed monitor may
not be stable. If the last digit is xed to "0," the
display status becomes stable.
Fixed
on
oFF
Not xed
oFF
Prevention of operation at
power-on alarm
opAL
If the power is supplied when the FWD input or
REV input is being ON, an alarm will generate.
When starting or stopping the motor by ON-OFF
control of the power supply, set this parameter to
OFF (Disable).
ON (Enable)
on
on
OFF (Disable)
oFF
External speed
command input
ES in
Selects the setting method of the rotation speed
for the operation data No.0.
When setting the rotation speed using an external
potentiometer or external DC voltage, set the
external speed command input to ON (Enable).
When this parameter is set to OFF (Disable),
the rotation speed can be set with the operation
panel.
ON (Enable)
on
oFF
OFF (Disable)
oFF
External speed command
voltage selection
EuSL
Selects "0 - 5 VDC" or "0 to 10 VDC" in
accordance with the external DC voltage used at
the time of the speed setting.
0-10 VDC
0-10
0-5
0-5 VDC
0-5
External speed command offset
EoSt
Adjusts the speed difference among motors when
performing multi-motor control.
−800 to +800 r/min 0
Speed upper
and lower
limit
SPL~n
Speed
upper limit
H i
Sets the upper limit of the rotation speed.
0, 90 to 1600 r/min
1600
Speed
lower limit
Lo
Sets the lower limit of the rotation speed. 0
Input
function
selection
in
IN0
in-0
Input signals assigned to input terminals can be
changed. Refer to p.31 for details.
FWD
F_wd
REV
rEu
M0
~n0
M1
~n1
ALARM-RESET
ArSt
FREE
FrEE
EXT-ERROR
E-Er
F_wd
IN1
in-1 rEu
IN2
in-2 ~n0
IN3
in-3 ~n1
IN4
in-4 ArSt
IN5
in-5 FrEE
Output
function
selection
oUt
OUT0
oUt0
Output signals assigned to output terminals can
be changed. Refer to p.31 for details.
SPEED-OUT
SP
ALARM-OUT
AL~n
TH-OUT
tH-o
WNG
_wnG
SP
OUT1
oUt1 AL~n
Motor lock detection time
~nLt~n
Sets the time needed to output an alarm after
detecting the lock state of the motor or the
disconnection of the motor cable.
1.0 to 5.0 s 5.0
Motor rotation direction
d ir
Sets the motor rotation direction when inputting
the FWD input.
CW
CCW
c _ w
cc_w
c_w
All parameters initialization
in i
Restores the value set in the parameter mode to
the initial value.
– –
Note
•
Do not turn the control DC power supply while the display is blinking after executing the data setting or
initialization. Doing so may damage the data.
•
When setting the speed increasing ratio to 1.00, the speed reduction ratio will be effective. When setting the
speed increasing ratio to other than 1.00, the speed increasing ratio will be effective.