Problem
Possible Cause
No power s upply
Water Full Indication Flashes
Solution
Connect to a functioning outlet and switch on
Drain water tank and reset it, or re-position
the water tank to right pla ce
Not
working
Room temperature ˂ 5°C,or Self-Protection designed to protect the unit.
˃
35 °C
Can not work under such temperature
Is the air filter clogged?
Clean the air filter as instructed
Bad
Is the intake duct or
Remove the obstruction from the discharge
duct or intake duct.
functioning
discharge duct obstructed?
No air
intake
Is the filter clogged?
Wash the filter
Is the ma chine put in the plat
place?
Loud noise
when
Put the machine on the plat ground
running
Is the filter clogged?
Wash the filter
E2
LO
Humidity sensor problem
Change a sensor
Environmental humidity is
below 20%
Environmental humidity is
above 90%
HI
CL
Low temperature protection, The dehumidifie r shuts down for self-
the environmental
temperature5
protection
High temperature protection,
the environmental
temperature38
CH
1
0.DECOMMISSIONING
STORAGE
Long-term storage - If you will not be using the unit for an extended period of time (more
than a few weeks) it is best to clean the unit and dry it out completely. Please store the unit
per the following steps:
1
2
3
4
5
6
. Press power button to switch off and unplug the unit.
. Drain the remaining water from the unit.
. Clean the filter and let the filter dry completely in a shaded area.
. Collect the power cord at the water tank.
. Re-install the filter at its position.
. The unit must be kept in upright position when in storage.
7. Preserving the machine in ventilating, dry, non- corrosive gas and safe place indoor.