LIB
ekor.rci
Integrated control unit
General instructions
IG-158-EN, version 09, 15/11/2016

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Ormazabal ekor.rci and is the answer not in the manual?

Ormazabal ekor.rci Specifications

General IconGeneral
TypeControl Unit
ManufacturerOrmazabal
Modelekor.rci
Operating Temperature-25°C to +70°C
CommunicationModbus RTU

Summary

General Description of the Ekor.rci Unit

General Functional Characteristics

Details the core functionalities and capabilities of the ekor.rci integrated control unit.

Parts of the Ekor.rci Unit

Identifies the main physical components of the ekor.rci unit, including the electronic relay and sensors.

Communications and Programming Software

Explains the communication ports and software used for configuring and operating the ekor.rci unit.

Applications of the Ekor.rci Unit

Remote Controlled Transformer Substation

Enables remote control and monitoring of transformer and switching substations.

Automatic Sectionaliser

Automatically disconnects fault sections of a line for improved network reliability.

Automatic Transfer

Minimizes power outages by automatically switching to a backup line.

Phase-to-Earth Fault Detection

Detects phase-to-earth faults, particularly in networks with low fault currents.

Cable Break Detection

Detects cable breaks by monitoring small unbalances in the system.

Earthing Prevention Interlocks

Prevents cubicle switch operation when voltage is detected on the line.

Detection, Automation, and Control Functions

Overcurrent Detection

Detects overcurrents for phase-to-phase and phase-to-earth faults using defined time curves.

Earth Ultrasensitive Device

Detects very low earth fault currents, suitable for specific network conditions.

Voltage Presence/Absence Detection

Detects the presence or absence of voltage in individual line phases.

Non-Directional Earth Fault Indication

Indicates phase-to-earth faults in solid or impedant neutral networks.

Directional Earth Fault Indication

Detects the direction of earth faults, crucial for capacitive or isolated neutral networks.

Zero-Sequence Voltage Metering

Measures zero-sequence voltage, used in directional fault determination.

Automatic Sectionalizer

Automatically disconnects fault sections of a line based on detected faults.

MV Monitoring

Monitors medium voltage parameters when the unit is equipped with an Ethernet module.

Switch Control

Controls the operation of the cubicle switch and monitors its status.

Remote Control

Enables remote monitoring and control of the unit via communication protocols.

Metering Functions

Current Measurement (I)

Measures RMS values of phase and zero-sequence currents.

Voltage Measurement (V)

Displays voltage presence/absence and measures phase/zero-sequence voltages.

Active Power Measurement (P)

Measures three-phase active power without the need for voltage transformers.

Reactive Power Measurement (Q)

Measures three-phase reactive power for electricity supply quality assessment.

Sensors

Functional Characteristics

Details toroidal-core current transformers with high ratio, encapsulated in self-extinguishing polyurethane.

Vector Sum / Zero-Sequence Wiring

Explains wiring configurations for current sensors, differentiating vector sum and zero-sequence methods.

Voltage Sensing

Describes how voltage is detected using capacitor dividers integrated into cubicle bushings.

RTU Function and Medium-Voltage Monitoring

MV Monitoring Functions

Transmits fault detection, measurements, alarms, and events via IEC 60870-5-104 protocol.

Hardware Characteristics

Details the RTU unit's front panel and its Ethernet port for connectivity.

Communication with Dispatching Centre

Uses the IEC 60870-5-104 protocol for communication with substations.

Web Server for Configuration

Provides web-based access for checking and modifying unit parameters.

Input/Output Configuration for RTU

Details the configuration of digital inputs and outputs for the RTU function.

Technical Characteristics

Rated Values

Lists key electrical and operational specifications of the ekor.rci unit.

Mechanical Design

Covers IK rating, IP rating, dimensions, weight, and connection types.

Insulation Tests

Details insulation resistance, electric strength, and voltage impulse tests.

Electromagnetic Compatibility

Lists tests for EMC compliance including ESD, radiated fields, and bursts.

Climatic Tests

Outlines tests for slow changes, dry heat, damp heat, and salt fog.

Mechanical Tests

Specifies sinusoidal vibration tests for response and endurance.

Power Tests

Details tests for load making/breaking and short-circuit capabilities.

CE Conformity

Confirms compliance with EU directives and international regulations.

ekor.rci Integrated Control Unit Details

Configurator

Tool to select unit based on installation characteristics and configure functions.

Functional Description

Explains the unit's use for automation, control, and fault detection in feeder cubicles.

Inputs/Outputs Definition

Details the physical inputs and outputs available for different modules.

Cubicle Installation

Describes the installation process and accessible parts of the ekor.rci unit.

Electrical Diagram

Shows the wiring connections between the unit's components.

Toroidal-Core Current Transformer Installation

Instructions for installing phase toroidal transformers in cubicles.

Checking and Maintenance

Procedures for performing operating tests and maintenance checks.

Busbar Connection Applications

Explains the unit's application in busbar connections for automation and control.

Setting and Handling Menus

Keypad and Display Overview

Describes the unit's keypad and alphanumeric display for user interaction.

Display Mode

Explains the normal operating mode for viewing system parameters and fault information.

Parameter Setting

Details how to access and modify various operational parameters.

Fault Recognition

Explains how the unit detects and displays different types of faults.

Menu Map (Quick Access)

Provides a summary of submenus for quick navigation and understanding.

Communications Protocols

Physical Medium: RS485 and Optical Fibre

Outlines the physical connection options for remote control communications.

MODBUS Protocol

Details the MODBUS RTU transmission mode for data communication.

PROCOME Protocol

Details the PROCOME protocol for communication, covering link and application levels.