Y-cable (splitter cable)
The Y-cable is necessary to split up the ethernet cable and the NMEA 2000
backbone.
The Ethernet cable must be connected to your boat LAN (Ethernet Hub, MFD,
etc.) or your onboard computer
To receive boat data OSCAR One must be connected to the boat bus backbone
(NMEA 2000).
Attention: Termination resistor is mounted inside OSCAR One Unit. A
separate backbone for OSCAR ONE with an NMEA bridge connection to the
boat backbone is highly recommended.
4.3. Connectors
Mast Data Cable:
Top: Amphenol LTW “BU-12BFFA-LL7001”
Circular Connector ASSY LOCK 12PIN F CONN F PIN
Bottom: Amphenol LTW “BD-08BMMA-QL8MP0”
Circular Connector ASSY LOCK 8PIN M CONN M PIN
Power Cable:
Top: Amphenol LTW “03BFFA-LL7001”
Circular Connector REC 3 Contacts Skt Cable Mount AD
Bottom: free cable end
Y-cable (Splitter):
Mast end: Amphenol LTW “BD-08BFFA-QL8MP0”
Circular Connector ASSY LOCK 8PIN F CONN F PIN
Boat bus: NMEA 2000 male connector (5 pin)
Boat LAN: RJ45 or brand specific connector (e.g. Raynet, B&G, etc.)
BSB GROUP I www.oscar-navigation.com I Page 13 of 16