Data sheet – MEC 1205 / MEC 1207 / MEC 1210
50% of rated current up to 11 V
5 A up to:
14.1 V (GEL)
14.4 V (AGM)
14.7 V (WET)
14.7 V (CALCIUM)
7 A up to:
14.1 V (GEL)
14.4 V (AGM)
14.7 V (WET)
14.7 V (CALCIUM)
10 A up to:
14.1 V (GEL)
14.4 V (AGM)
14.7 V (WET)
14.7 V (CALCIUM)
Constant voltage until the
current drops to
0.75 A
Constant voltage until the
current drops to
1.05 A
Constant voltage until the
current drops to
1.5 A
Monitors the voltage for 90 seconds
Continuous current (0.75 A) for
30 minutes or for 4 hours limited
to:
14.1 V (GEL)
14.4 V (AGM)
16 V (WET)
16 V (CA)
Continuous current (1.05 A) for
30 minutes or for 4 hours
limited to:
14.1 V (GEL)
14.4 V (AGM)
16 V (WET)
16 V (CA)
Continuous current (1.5 A) for
30 minutes or for 4 hours
limited to:
14.1 V (GEL)
14.4 V (AGM)
16 V (WET)
16 V (CA)
Preservation Charge (Float)
13.7 V - also with pulse function
Maintenance Charge (Pulse)
12.6 V - 14.1 V, 5-2 A (GEL)
12.6 V - 14.4 V, 5-2 A (AGM)
12.6 V - 14.7 V, 5-2 A (WET)
12.6 V - 14.7 V, 5-2 A (CA)
Automatically temperature controlled
-20 °C to +50 °C, the output power is automatically reduced at too high temperatures.
Over Votlage Protection
(Surge)
Automatic protection function that turns off the device at a voltage of more than 17.5 V.
All 12 V lead-acid batteries - including Calcium, WET, Gel, AGM and non-woven batteries