What to do if LP Gas is running low in my Paloma PH-28RIFSN?
- JJacqueline WilkinsonJul 30, 2025
To solve this issue with your Paloma Water Heater (LP models only), fill up the LP Gas container or replace it with a new cylinder of LP Gas.
What to do if LP Gas is running low in my Paloma PH-28RIFSN?
To solve this issue with your Paloma Water Heater (LP models only), fill up the LP Gas container or replace it with a new cylinder of LP Gas.
How to fix Paloma PH-28RIFSN Water Heater with not enough or no hot water?
If your Paloma Water Heater isn't producing enough hot water or any at all, several factors could be at play. First, ensure the shutoff valve and the hot water faucet are fully opened. Check for frozen water pipes and allow them to thaw if necessary. Verify that the unit is properly powered and has an adequate water supply. Make sure the unit is turned 'ON' via the remote control. The temperature setting might be too low, so increase it accordingly. If your system has a mixing valve, inspect it for malfunctions and replace it if needed. Lastly, if there's an error code on the remote, consult the error code instructions; if the problem persists, contact a dealer for service.
Why is my Paloma PH-28RIFSN Water Heater water not hot enough?
If the water from your Paloma Water Heater isn't hot enough, it might be due to a simple issue. Try increasing the temperature setting on the unit. Also, ensure that the gas valve is fully opened to allow for proper heating.
What to do if Paloma PH-28RIFSN Water Heater water is too hot?
If the water from your Paloma Water Heater is too hot, there are a few things you can check. First, decrease the temperature setting on the unit. Also, make sure the water shutoff valve is fully opened. If only a small amount of water has been heated, allow more water to flow through the system.
Why does the fan continue to rotate after closing the hot water faucet on my Paloma PH-28RIFSN?
The fan continuing to rotate after the hot water faucet is closed on your Paloma Water Heater is normal operation. This function ensures hot water is available when the faucet is reopened, so there's no need to call for service.
What to do if the hot water faucet is not opened enough on my Paloma Water Heater?
To fix this, open the faucet more to ensure enough water volume is flowing through your Paloma Water Heater.
What to do if air intake is blocked on Paloma Water Heater?
To solve this, remove any obstructions blocking the air intake or vent termination of your Paloma Water Heater.
Brand | Paloma |
---|---|
Model | PH-28RIFSN |
Category | Water Heater |
Language | English |
Emphasizes the critical need for proper venting to prevent fire, explosion, or carbon monoxide risks.
Warns against storing or using flammable liquids near the water heater due to explosion or fire risks.
Highlights the danger of water temperatures over 125°F causing severe burns or death from scalding.
Details dangers associated with natural and LP gas, including conversion warnings and leak detection.
Outlines California law requiring seismic bracing for water heaters.
Advises on shutting off gas, reading manuals, proper usage, installation, and avoiding unauthorized repairs.
Guidelines for choosing a suitable installation location, avoiding damage and flammable vapor risks.
Explains requirements for adequate air supply for combustion and ventilation in different spaces.
Warns against operating in environments with halogenated hydrocarbons that can damage the unit.
Instructions to check for shipping damage and verify gas type match with the unit's rating plate.
Details on how to securely mount the water heater to the wall using brackets and appropriate fasteners.
Guidance on plumbing connections, material requirements, pressure, and water flow rates for proper operation.
Mandates installation of a new pressure relief valve, specifying standards, pressure ratings, and discharge piping.
Instructions for connecting the gas supply line, including shutoff valves, pipe material, and pressure requirements.
Procedures for testing gas connections using soapy water to detect leaks before and after operation.
Guidelines for safely disconnecting the water heater during gas supply system pressure testing.
Information regarding appliance ratings at different elevations and potential component replacement.
Explains that insulation blankets are not necessary for this tankless unit and may void the warranty.
Recommends insulating hot and cold water pipes for freeze protection and energy efficiency.
Details maximum allowable vent pipe lengths and elbow configurations to ensure proper system operation.
Instructions for insulating vent pipes passing through closed spaces and maintaining clearances.
Requirements and installation procedure for the UL-approved vent adapter for connecting the vent to the unit.
Recommendations for installing a condensate trap and drain to prevent acidic condensate backup.
Specifies minimum clearances and considerations for locating the horizontal vent terminal on the building exterior.
Provides advice on vent terminal placement, protection from moisture, and insulation of exposed pipes.
Step-by-step guide for installing the wall thimble for horizontal vent termination, including support and sealing.
Details minimum clearances and considerations for locating the vertical vent terminal on the roof.
Instructions for installing vent pipes vertically through the roof, including flashing and termination details.
Specifies the 120VAC/60Hz, 2 Amp power requirement and use of a grounded outlet.
Details requirements for hardwiring, including compliance with codes and proper grounding.
Crucial safety warnings before operation, including gas leak detection and proper knob usage.
Step-by-step guide for safely lighting and operating the water heater.
Procedures for safely shutting off the gas supply to the appliance for service or emergencies.
Essential safety measures for operating the water heater, including valve operation and combustible material handling.
Guidance on setting water temperature, risks of scalding, and the use of mixing valves.
Recommended periodic inspections and maintenance tasks for reliable water heater operation.
Instructions for cleaning the unit, maintaining clearances, and ensuring proper ventilation.
Step-by-step guide for cleaning the air intake filter to ensure proper unit function.
Methods for cleaning the water heater and remote control surfaces safely and effectively.
Annual inspection guidelines for the venting system to ensure it is secure and air-tight.
Guidance on visually inspecting the main burners for proper flame pattern and operation.
Procedures for safely preparing the water heater for extended periods of non-use.
Detailed steps for safely draining water from the heater to prevent damage or injury.
Methods and precautions for protecting the water heater and piping from freezing conditions.
A guide to identifying and resolving common problems with the water heater before contacting service.
Explains various error codes displayed by the unit and provides corresponding troubleshooting steps.
Steps for ordering replacement parts, including necessary information and contact details.
Defines the scope and availability of the limited warranty for original owners of the water heater.
Specifies the duration of warranty coverage for the heat exchanger and other component parts.
Lists conditions and circumstances that are not covered by the limited warranty.
Clarifies Paloma's coverage for labor, shipping, and processing costs related to warranty claims.
Provides instructions on how to initiate a warranty claim and the required documentation.
Outlines the terms of the exclusive warranty and limits Paloma's liability for damages.