Parameter
No.
Function name Data setting value
Safety sensor must be input in the main controller of the lift, and in
the terminal of the main controller, operate the obstacle detection
of the automatic door.
obstacle detection function of the inverter does not operate in
CLOSE arrival area.
Dual security measures must be taken.
Failure to do so could lead to injury.
Caution
Apply obstacle detection function of the automatic door after security
and function operation of the lift is completely confirmed.
Failure to do so could lead to injury.
Used to set the parameter of obstacle detection function(current detection)
of the automatic door.
If motor overload is detected by current and reach obstacle judgment level, the
automatic door will carry out the fault ON operation.
Used to set validity of function, current detection level detected by overload and
detection judgment time with these parameters.
(See page 73, the "supplementary explanation of obstacle detection function".)
Overload detection frequency 1P59
Overload detection frequency 2
0.5 to 250Hz
0.5 to 250Hzǂ
P60
Overload detection current 1
P61 0.1 to 100A
Overload detection current 2
P62
0.1 to 100A
Overload detection judgment time
P63
0g1 to 999 ms("0" is set to no obstacle
detection function.)
Current
detection level
Current
P59
P61
P62
P60
Frequency
Detection
range
Current detection level is set with the four
setting values of P59 to P62.
If the output current is higher than current
detection level, sandwich of automatic door is
judged and the automatic door carries out
fault ON operation.
The judgment time for obstacle detection can
be set with parameter P63.
59
OVERLOAD DETECTION FREQUENCY 1, 2 (Parameter P59 and P60)
OVERLOAD DETECTION CURRENT1, 2 (Parameter P61 and P62)
OVERLOAD DETECTION JUDGMENT TIME (Parameter P63)