䃂㩷
Communication Function
The following functions are available depending on communications.
Function
Register No.
Relay No.
Function name Remarks
DT129 Output frequency 0.01Hz unit
DT130 Output current 0.1A unit
DT131 Output voltage 0.1V AC unit
DT132 Internal DC voltage 0.1V DC unit
DT133 Setting frequency 0.01Hz unit
DT134 Detection frequency 0.01Hz unit
DT135 Door position area 0 : OPEN arrival 1-6 : OPEN operation
7 : CLOSE arrival 8-13 : CLOSE operation
DT136 Door position 1unit (data type 1)
DT137
OPEN arrival position data
1unit (data type 1)˴
DT138
No. of door switching
1time (data type 1)˴
DT139
Encoder detection status
0.01kHz unit
+ : FWD - : REV
(data type 3)
(data type 3)
(data type 2)
(data type 2)
(data type 2)
(data type 3)
(data type 3)
DT140
Fault details 1 (latest)
DT141
Fault details 2 (second to latest)
DT142
Fault details 3 (third to latest)
DT143
Fault details 4 (fourth to latest)
Refer to the next page for the contents
of the data.
R144 غ
Control input terminal state
Contact data
R145 غ
Control output terminal state
Contact data
R146 غ Operation status Contact data
Monitor
R147 غ
Operation control status
Contact data
DT237
Without memory
DT238
Frequency
setting
With memory
0.01Hz unit (data type 3)
R250 غ Operation control Contact data
DT253
Fault reset command
0x9696
Control/
Command
DT255
Emergency stop command
0x9696
Setting
DT0غغغ
(Parameter No.)
Parameter setting
P region
: Register No. = Parameter No.
d region :
Register No.= Parameter No.+256
Note1) "ƶ" suffixed to the relay number means the specified position for BIT
(hexadecimal 0 to F). For the details on the functions of each BIT, refer
to each functional descriptions.
Note ) Rrefer to the next page for the explanation of the data type mentioned in
the above table.
79