No.
Item Ref. Illustration Procedure
2-16
14 F-lock lever
<Disassembly>
Dew sensor:
1)Remove the screw (S5) and remove the DEW sen-
sor.
E.G. roller arm assembly:
1)Remove the screw (S2) and remove the E.G. roller
arm assembly.
<Assembly>
1)Reverse the disassembly procedure.
<Disassembly>
1)Slide the F-lock lever in the direction of the arrow
to remove.
<Assembly>
1)Reverse the disassembly procedure.
15 Dew sensor/ E.G. roller arm assembly
Fig. 2.6.14
Fig. 2.6.15
F-lock lever
Long Hole Cross-section
Multemp SH-P
See
M3
in section 5.
(
S2
)
(
S5
)
E.G. roller arm assembly
DEW sensor
Note:
The E.G. roller arm assembly has undergone
perpendicularity management after being as-
sembled, so when replacement is required, it
will be necessary to replace the entire mecha-
nism assembly.