3-5
2 ME recording
current
adjustment
EE
ADJUST
MENU, 105.
ME REC
CURRENT
(4) Measure TP6 (SPA) by triggering TP5 (HID) and
confirm that the values a and b are within the
specified ranges.
(5) Press the [PLAY] button a few times to dis-
play the adjustment data in the "DATA:" field.
(The DATA value should not be 00000000 or
FFFFFFFF.)
(6) Press the [SET] button to store the adjustment
data.
*
Monitor display
-
[PLAY] and [STOP]
buttons
+
SET DATA = 115
Measuring
Measuring point (
*
)
No. Item instruments & Mode
Adjustment parts (
-
)
Adjustment procedure
Input signals
Adjustment level (
+
)
(1) Select ADJUST MENU No. 105, "ME REC
CURRENT".
(2) Check the set data so that the value is “115”
(Recording current is approx. 360 mVp-p). If not,
adjust the value to “115”
(3) Press the [SET] button to store the adjustment
data.
Fig. 3.2.1(2)
––– ADJUST MENU –––
100.PB S
W
P
O
INT
!
VR DATA : ----
CTL DATA : 120
SET DATA : 120
DATA : 00000000
Press the [PLAY] button a few
times to display data.
After displaying the data, press
the [SET] button to complete the
adjustment.
––– ADJUST MENU –––
105.ME REC CURRENT
VR DATA : 115
CTL DATA : 115
SET DATA : 115
CH1 6 55 3 5
CH2 6 55 3 5
Fig. 3.2.2
NOTE:
Make sure that the data value is displayed
before pressing the [SET] button. If this ad-
justment is completed before the data value
is displayed the adjustment value will not
be put into the memory.