3-7
Measuring
Measuring point ( )
No. Item instruments & Mode
Adjustment parts ( )
Adjustment procedure
Input signals
Adjustment level ( )
4 FS PLL 48
kHz adjust-
ment
Frequency
counter
No input
EE
ADJUST
MENU, 110. FS
PLL 48 kHz
(1)Select ADJUST MENU No. 110, "FS PLL 48
kHz".
(3)Adjust the frequency to the specified value.
(2)Press the [SET] button to measure frequency.
(4)Press the [SET] button to store the adjustment
data.
TP4 (FS PLL)
GND: TP1 (GND)
[Rewrite board]
[PLAY] and [STOP]
buttons
12.288 MHz 0.1
MHz
5 FS PLL
44.1 kHz
adjustment
Frequency
counter
No input
EE
ADJUST
MENU, 111.
FS PLL
44.1 kHz
(1)Select ADJUST MENU No. 111, "FS PLL 44.1
kHz".
(3)Adjust the frequency to the specified value.
(2)Press the [SET] button to measure frequency.
(4)Press the [SET] button to store the adjustment
data.
TP4 (FS PLL)
GND: TP1 (GND)
[Rewrite board]
[PLAY] and [STOP]
buttons
11.2896 MHz 0.1
MHz
6 FS PLL 32
kHz adjust-
ment
No input. EE
ADJUST
MENU,112. FS
PLL 32 kHz
(1)Select ADJUST MENU No. 112, "FS PLL 32
kHz".
(3)Adjust to the same value as the FS PLL 48
(2)Press the [SET] button to measure frequency.
kHz adjustment value. (Setting range: 0 to 255)
(4)Press the [SET] button to store the adjustment
data.
Monitor display
[PLAY] and [STOP]
buttons
Value adjusted in No.
110, "FS PLL 48 kHz"
in item 4 above.
7 27 MHz VCO
center
frequency
adjustment
Frequency
counter
No input
EE
ADJUST
MENU,113.
27 MHz VCO
(1)Select ADJUST MENU No. 113, "27 MHz VCO".
(3)Adjust the frequency to the specified value.
(2)Press the [SET] button to measure frequency.
(4)Press the [SET] button to store the adjustment
data.
TP7 (MAIN VCO)
GND: TP1 (GND)
[Rewrite board]
[PLAY] and [STOP]
buttons
13.5 MHz 0.1 MHz