1-11
1.8.7 ERROR HISTORY menu
It can display 4 errors that have occurred in the past.
Initially, when there is no error history in the memory, the first error to occur will be logged in the first position (HISTORY-1). The second
and third errors to occur will be logged in (HISTORY-2) and (HISTORY-3). All subsequent errors will be overwritten in (HISTORY-4).
The fourth and subsequent errors are set to overwrite in order to prevent the user from repeatedly attempting to use a malfunctioning unit
and thereby erasing any record of the initial cause error. Be sure to clear the error history before returning a repaired unit to the customer.
When resetting ERROR HISTORY, set the parameter for “CLEAR” to “EXECUTE”, and press the [SET] button.
Fig. 1.8.7 (1) ERROR HISTORY
(1) MECHANISM INFO (Detailed information when error occurs)
Move the cursor to the error code on the “ERROR HISTORY” screen, and press the [SET] button (or : button) to display the
MECHANISM INFO screen as it was at the time of the error, you can check the details of the malfunction.
Fig. 1.8.7 (2) MECHANISM INFO Display Screen
(HISTORY–1) 7101
––– ERROR HISTORY – ––
CAP MOTOR FA I LURE
(HISTORY–2) 7101
CAP MOTOR FA I LURE
(HISTORY–3) 7101
CAP MOTOR FA I LURE
(HISTORY–4) 7101
CAP MOTOR FA I LURE
CREAR CANSEL
PAGE BACK
First error display
Error Name Display
Second error display
Third error display
Latest error display
(Fourth and later are
overwritten on here)
Error Codes
M.POSI BRK2FAST>BRK2FAST
– – – M E C H A N I S M I N F O 2 / 2 – – –
H.POSI INIT >CASS IN
CAP [OFF F
W
D]REL[OFF F
W
D]
DRM[OFF] DIR[F
W
D]
DRV[00]CAPV[00]RELV[00]
MCV/SPD[00]RELI [00]
BGN[OFF]END[ON ]CAS[OFF]
STD[OFF ] H
W
[OFF] H
W
2[OFF]
SPL[OFF]THIN[ON ]
PAGE BAC
P.TM 000000H
––– M E CHANISM INFO 1/ 2 – ––
SYS MODE : PLAY( 01 , 00 )
MSD MODE : PLAY ( 0 1 , 0 0 )
–>STOP(00, 00)
LAST KEY:PLAY(00 , 00 )
TAPE REM[ 0000 ]
DE
W
[00] TEMP[00]
DIAMETER TU[00] SP[00]
NEXT PAGE
PAGE BACK