1-12
P. T M
SYS MODE
MSD MODE
LAST KEY
TAPE REM
DEW
TEMP
DIAMETER
M. POSI
H. POSI
CAP
REL
DRM
DIR
DRV
CAPV
RELV
POWER HOUR METER
SYSCON CPU mode when error occurred
PLAY (03, 00)
MSD CPU mode and target mode when
error occurred
PLAY (01, 00)
Final Key code when error occurred
PLAY (E7, 01)
TAPE REMAIN
DEW sensor A/D intake value
Temperature sensor A/D intake value
The value "49" [5C] is threshold of
detecting low temperture.
The value "DC" [60C] is the threshold of
displaying "OVER HEATING" message.
Displays wound tape diameter (Take-up, Supply)
Mechanism position and target mechanism
position
Housing position and target housing position
Capstan status
Reel status
Drum status
Direction of tape running (Direction of target)
Drum control voltage
Capstan control voltage
Reel control torque value
Power hour meter is display.
SFF/SREW parameter is speed display.
(Refer to Fig. 1.8.7 (2) Speed parameter)
Parameters of other modes are irrelevant.
EJECT (01) : Eject ADUB (0B) : Audio Dub
STOP (02) : Stop ADBP (0C) :
Audio Dub Pause
PLAY (03) : Play REC (13) : Rec
STL (04) : Still RECP (14) : Rec Pause
FF (05) : FF DVRC (15) : DV Rec
REW (06) : Rew DVRP (16) : DV Rec Pause
SFF (07) :
Search Fwd
POFF (1A) : Power Off
SREW (08) :
Search Rev
NDEF (1F) :
During initial operation
SFF/SREW parameter is speed display (See Fig. 1.8.7(2))
Other parameters are 01: ON, 00: OFF
REC (E0) : Rec SFF (EB) : Search Fwd
RECP (E1) : Rec Pause SREW (EC) : Search Rev
DVRP (E2) :
DV Rec Pause
STOP (F0) : Stop
ADUB (E5) : Audio Dub EJECT (F1) : Eject
ADBP (E6) :
Audio Dub Pause
HWUP (F2) : Housing Up
PLAY (E7) : Play HWDN (F3) : Housing Down
STL (E8) : Still POFF (F4) : Power Off
FF (E9) : FF DVRC (F5) : DV Rec
REW (EA) : Rew PON (FA) : Power on
Displays tape remaining in minutes ([FFFF] : not detected)
DEW detects (at low temp. [13], at normal temp [CD])
DEW off (at low temp. [12], at normal temp [99])
Temperature is displayed in hexadecimal value.
-10!C
a
[22] 20!C
a
[7C] 50!C
a
[CC]
- 5!C
a
[2D] 25!C
a
[8C] 55!C
a
[D4]
0!C
a
[3A] 30!C
a
[9C] 60!C
a
[DC]
5!C
a
[49] 35!C
a
[AA]
10!C
a
[59] 40!C
a
[B7] 65!C
a
[E1]
15!C
a
[6A] 45!C
a
[C2] 70!C
a
[E6]
[00]—[FF] : 0mm-82mm (Diameter) ([00] is non-detected)
[2ULD], [ULD2BRK], [BRK], [BRK2FAST], [FAST],
[FAST2STP], [STP], [STP2SRH], [SRH], [SRH2], [INIT]("2" is
the meaning of "TO". It means transition. Refer to section 2,
Mechanism Timing Chart.)
[EJECT], [EJECT2IN], [CASS IN], [RELEASE](Release the
SUP reel lock.)
[INIT]
(For the intake and eject operation, refer to section 8.2.3.)
[ON] : Rotate [FWD/REV]: Direction display
[OFF] : Stop
[ON] : Rotate [FWD/REV]: Direction display
[OFF] : Stop
[ON] : Rotate
[OFF] : Stop
[FWD/REV] : Direction display
[00-FF] : 0—3V
[00-FF] : 0—3V
[00-FF] : 0—3A
ParameterMODE DATA
ParameterMODE DATA
ParameterMODE DATA
Item Content Displayed Content