1-13
MCV/SPD
RELI
BGN
END
CAS
STD
HW, HW2
SPL
THIN
Loading/cassette housing control voltage
(when error code 4xxx and error code 3xxx
is displayed.)
Tape speed (When the code excepting
error code 4xxx and error code 3xxx is
displayed.)
Reel current (Cassette housing motor
current during housing-related warning)
Begin sensor
End sensor
Cassette SW status
Standard cassette SW status
Housing SW/Housing 2SW status
SUP Lock SW status (during loading)
Thin tape detection
[00-FF] : 0—8V (Displays mode motor control voltage
during error code 3xxx )
[00-FF] : 0-11V (Displays cassette motor control voltage
during error code 4xxx)
[00-FA] : 0—25X (FF is displayed when the speed is faster
than this.)
“Tape speed” is a function to convert the
hexadecimal value into a decimal value,
and no speed parameter of the tape.
(ex. FAh = 250 " The speed is 25.0X.)
[00-FF] : 0—1.2A
[ON] : Leader tape detected
[OFF] : Magnetic tape detected
[ON] : Trailer tape detected
[OFF] : Magnetic tape detected
[OFF] : No cassette
[ON] : Cassette detected (STD/MINI)
[OFF] : Mini cassette tape inserted
[ON] : STD cassette tape inserted
[ON] : Normal operation (TU side tape winding)
[OFF] : Lock release
(Tape begin detected, Supply side tape winding mode)
[ON] : THIN
[OFF] : NORMAL
HW SW HW2 SW Housing status
[OFF] [ON] –
[ON] [OFF] EJECT (Initial position)
[OFF] [OFF] Cassette intake
[ON] [ON] Ejecting Mini cassette
Item Content Displayed Content
Table 1.8.7 (1) MECHANISM INFO content
Table 1.8.7 (2) Speed parameter
Parameter Speed Parameter Speed
00 x 0 82 x 1.08
1F x 0.03 83 x 1.11
40 x 0.10 84 x 1.12
53 x 0.20 85 x 1.16
61 x 0.30 91 x 2.00
6D x 0.50 A9 x 5.00
7A x 0.80 BD x 9.00
7B x 0.84 C0 x 10.0
7D x 0.90 C4 x 12.0
7F x 0.96 CC x 15.0
80 x 1.00 D3 x 20.0
81 x 1.04