INF-32
7-1-2. Save data of SYS EEPROM
1. This camera recorder is set to CAM mode.
2. Select “SYSCON(S
)” section after start up the PC EVR software, and click “OK” button.
3. Select “EEPROM Read(R
)” in “File(F)” menu and “16K” is selected on EEPROM Read screen.
4. Click “OK” button and reading starts.
5. Green is displayed to the status lamp while reading it. When reading is completed, the status lamp changes
into a blue display.
6. Select “Save Image File(S
)” in “File(F)” menu.
7. Click “Send(S
)” button after the file name is input, and the place that saves a file is specified on SAVE screen.
The following message is displayed when saving a file.