ELE-21
4. SYNC
4-1. Setting Method
1. Set the switches of camera recorder as shown
below.
SHUTTER :OFF
GAIN :L
OUTPUT :BAR
WHITE BAL :PRE
2. Connect the cables as shown below with the
Camera Recorder and the EVR power OFF.
4-2. 4fsc VCO Adjustment
BOARD
SYNC
TP
TP3101
ADJUST
VR3104
INPUT
-
MODE
CAMERA BAR
M. EQ.
Frequency Counter
SPEC.
NTSC : f=14.31818MHz +/- 10Hz
PAL : f=17.734475MHz +/- 10Hz
1. Connect a frequency counter at
TP3101
and adjust
VR3104
so that the frequency is in the
specification.
4-3. 27MHz CLOCK Adjustment
BOARD
SYNC,DSP
TP
TP15 [27MHz]
TP14 [HD] (DSP)
ADJUST
VR3002 (SYNC)
INPUT
-
MODE
CAMERA BAR
M. EQ.
Oscilloscope
SPEC.
A=12ns +/- 2ns
1. Connect an oscilloscope to
TP15 (27MHz)
,
TP14
(HD)
and adjust
VR3002
so that the
A
is in the
specification.
TP15
(27MHz)
AJ-
D610WB