Loading...
ELE-22
4-4. SCH PHASE Adjustment
BOARD
SYNC
TP
CAM OUT
ADJUST
VR3102
INPUT
-
MODE
CAMERA BAR
M. EQ.
SCH meter
SPEC.
SCH = 0+/-2 Degrees
1. Adjust
VR3102
so that the SCH of the
CAM OUT
is in the specification.
<NTSC>
<PAL>
4-5. SYSTEM PHASE Adjustment
(1)
BOARD
SYNC
TP
CAM OUT
ADJUST
VR3103 [SYSTEM H PHASE], EVR
INPUT
Any composite signal
(GENLOCK IN)
MODE
CAMERA BAR
M. EQ.
SCH meter
SPEC.
A = less than 3 us
1. Supply a composite signal to the
GENLOCK IN
and set the GENLOCK MODE to the
“EXT”
in the
ENG MENU (GENLOCK/IRIS page).
2. Set the EVR as shown below.
COM:[1E] DATA:[14] ADR:[00] [Enter]
3. Adjust
VR3103
so that the Sync phase of
GENLOCK signal is the same phase as the CAM
OUT.
BURST
H
A
GENLOCK
IN
CAM OUT