Aquarea air/water heat pump – Installation manual for compact systems 03 / 2013
4
Location /
Installation
4 15
Location / Installing the device
Installation
4.2 Installation
Danger! At least four persons are required for installation work. Otherwise, the
weight of the device can lead to injuries.
Transport and lifting equipment must be suitable for the device weight.
If possible, the device should only be moved with the appropriate trans-
port and lifting equipment. The lifting equipment can be attached to the
base structure of the device using lugs.
³ Transport the device to the planned installation location.
³ Remove the packaging carefully.
³ Fasten the device with four M12 anchor bolts
(tightening force > 15,000 N)
Transport the device carefully to avoid damage. That includes placing /
lowering the device in the installation location.
For installation locations which can be impacted by strong winds, e.g.
wind between buildings, including building roofs, the compact unit must
be secured on-site with additional anchoring to prevent it toppling over.
1
Floor
2
Stone / gravel
3
&RQFUHWHRUÁRRUSODWH
4
Anchor bolt
60
mm
300
mm
>
20
mm
80
mm
4
3
3
4
2
1
Protection against toppling over via anchoring
0LQLPXPUHTXLUHPHQWVIRUDQFKRULQJWKHFRPSDFWXQLWWRWKHÁRRURUDIRXQGDWLRQOHIWRUGLUHFWO\WRDEDVHSODWHULJKW
Compact unit drilling template
980
1,280
355.5
320