7 – 22 Aquarea air/water heat pump – Installation manual for compact systems 03 / 2013
Electrical installation
7 Electrical installation
Correct Incorrect Correct Incorrect Incorrect
10 mm ± 1
min. 5 mm
The clearance
between the
cables must be
at least 5 mm.
The insulation must be at least 10 mm +/- 1 mm in length. Ensure that all strands are clamped.
Clamping screw connection Tightening torque (NM)
M4 157 – 196
M5 196 – 245
Danger! 7KHZRUNPD\RQO\EHSHUIRUPHGE\TXDOLÀHGRUFHUWLÀHGSHUVRQQHO
Ensure that you have disconnected the power supply before you per-
form installation work. Secure the power supply to prevent unintentional
reactivation.
Ensure that all cables have the correct polarity. If this is not the case,
HOHFWULFVKRFNVRUÀUHFDQUHVXOW
Ensure that the cables can never come into contact with hot objects
such as the water pipes. High temperatures can damage the insulation.
2EVHUYHWKHIROORZLQJVSHFLÀFDWLRQVIRULQVWDOODWLRQ