7 – 31Aquarea air/water heat pump – Installation manual for compact systems 03 / 2013
7
Electrical
installation
Electrical installation
Installing the wired remote control
Laying concealed cables
You can lay the wired remote control cable so that it is concealed
or visible:
1
2
8
7
3
4
5
6
1
Upper cover
2
Upper clamp
3
Plug connector (CON1)
4
Lower cover
5
Screw
6
Lower clamp
7
Flush-mounted box
8
Remote control cable
1
Upper cover
2
Cable outlet to the rear
3
Lower cover
4
Tabs
5
Upper cover
6
Cable connection (CON1)
5
4
3
6
1
2
Laying cables in
the wired remote
control
Laying concealed cables
7.3.1 Laying concealed cables
³ ,QVHUWDÁXVKPRXQWHGER[WREHSURYLGHGE\WKHFXVWRPHULQWRWKH
wall (medium-sized
rectangular socket, Panasonic part no. DS3744
or similar).
³ Insert the wired remote control cable into the socket.
³ Route the concealed wired remote control cable to the wired remote
FRQWURODVVKRZQLQWKHÀJXUH
³ Use the two supplied M4 × 30 screws
WRIDVWHQWKHORZHUFRYHURIWKHUHPRWHFRQWUROWRWKHÁXVKPRXQWHG
socket. Ensure that the lower cover is not under strain and do not
tighten the screws excessively. Use only the supplied screws.
³ Fasten the connection of the remote control cable to the plug
connector (CON1) in the upper cover of the circuit board. Ensure
that is securely attached.
³ Secure the upper cover to the lower cover of the remote control using
the clamps provided.
Danger!
Lay the cable as shown in
WKHÀJXUHDERYHVRWKDWWKH
housing of the wired remote
control can be closed securely.
Warning!
In cavity walls, use a bushing
for the wired remote control
cable to prevent rodents biting
the wire.