7 31Aquarea air/water heat pump – Installation manual for compact systems 03 / 2013
7
Electrical
installation
Electrical installation
Installing the wired remote control
Laying concealed cables
You can lay the wired remote control cable so that it is concealed
or visible:
1
2
8
7
3
4
5
6
1
Upper cover
2
Upper clamp
3
Plug connector (CON1)
4
Lower cover
5
Screw
6
Lower clamp
7
Flush-mounted box
8
Remote control cable
1
Upper cover
2
Cable outlet to the rear
3
Lower cover
4
Tabs
5
Upper cover
6
Cable connection (CON1)
5
4
3
6
1
2
Laying cables in
the wired remote
control
Laying concealed cables
7.3.1 Laying concealed cables
³ ,QVHUWDÁXVKPRXQWHGER[WREHSURYLGHGE\WKHFXVWRPHULQWRWKH
wall (medium-sized
rectangular socket, Panasonic part no. DS3744
or similar).
³ Insert the wired remote control cable into the socket.
³ Route the concealed wired remote control cable to the wired remote
FRQWURODVVKRZQLQWKHÀJXUH
³ Use the two supplied M4 × 30 screws
WRIDVWHQWKHORZHUFRYHURIWKHUHPRWHFRQWUROWRWKHÁXVKPRXQWHG
socket. Ensure that the lower cover is not under strain and do not
tighten the screws excessively. Use only the supplied screws.
³ Fasten the connection of the remote control cable to the plug
connector (CON1) in the upper cover of the circuit board. Ensure
that is securely attached.
³ Secure the upper cover to the lower cover of the remote control using
the clamps provided.
Danger!
Lay the cable as shown in
WKHÀJXUHDERYHVRWKDWWKH
housing of the wired remote
control can be closed securely.
Warning!
In cavity walls, use a bushing
for the wired remote control
cable to prevent rodents biting
the wire.