11 – 52 Aquarea air/water heat pump – Installation manual for compact systems 03 / 2013
Appendix
Commissioning report
Commissioning report
Parameter list
Low outside temperature
Out Lo in °C
Function
Operating mode/
Operating display
High outside temperature
Out Hi in °C
Pry HEAT
Heating priority
Yes No
Water supply target temperature at out Lo
H
2
O Lo in °C
Note: Setting heating priority
over hot water heating
Water supply target temperature at out Hi
H
2
O Hi in °C
int HEAT
Duration of heating in heating and hot water mode in hours
Target temp. to deactivate heating mode
Heating limit temperature in °C
int TANK
Duration of hot water heating in heating and hot water mode in h
Outside temperature for activating the additional
electric heater in °C
Booster htr
Water heating
Yes No
Water supply target temperature in cooling mode
in °C
dly BOOSTER
Switch-on delay for electric immersion heater for hot-water
tank in hours
Target temperature of the hot-water tank in °C
Fun StrL
Sterilisation
Yes No
Str
Day and time of sterilisation
boi StrL
Sterilisation temperature in °C
Note: At sterilisation temperatures over 55 °C, the electric
immersion heater for the hot-water tank is always used
oPr Str
Sterilisation period in min
The parameters from Pry on are only shown
if TANK is set to Yes
The parameters int to dly are only shown
if Heating priority is set to No
The parameters Fun to oPr are only
for FRQÀJXULQJVWHULOLVDWLRQ
Pump level
Level 1
Yes No
Level 2
Yes No
Level 3
Yes No
Function
Operating mode /
Operating display
con room
External room thermostat
Yes No
Heater cap
Selection of the output of the additional electric
heater for the heat pump
3 kW 6 kW 9 kW
con TANK
Connection of hot-water tank
Yes No
Pry SOLAR
Solar priority
Yes No
Note: Set to Yes where possible, as otherwise the
service water is mainly heated by the heat pump
instead of solar thermal energy